Disturbance Formalization: The U_c / W Partition

Motivation

The standard GDS canonical form treats all BoundaryAction outputs as a single exogenous signal space Z:

g : X x Z -> D       (policy / input map)
f : X x D -> X       (state transition)
h = f . g            (composition)

In practice, not all exogenous inputs pass through the decision layer g. Some inputs -- wind gusts, sensor noise, market shocks -- enter the state dynamics f directly, bypassing any policy or control logic. These are disturbances.

The Partition

We split Z into two disjoint subspaces:

Space Name Description
U_c Controlled inputs Exogenous signals that feed the policy map g
W Disturbances Exogenous signals that bypass g and enter f directly

The extended canonical form becomes:

g : X x U_c -> D          (policy / input map)
f : X x D x W -> X        (state transition with disturbances)
h = f(-, g(-, -), -)       (composition)

When W is empty, this reduces to the standard form.

Tagging Convention

Disturbance inputs are declared by tagging a BoundaryAction block with role="disturbance":

import gds

wind = gds.BoundaryAction(
    name="Wind Gust",
    interface=gds.interface(forward_out=["Force"]),
    tags={"role": "disturbance"},
)

The tag is semantic metadata -- it does not change block construction, composition, or compilation. It only affects:

  1. Canonical projection: project_canonical() partitions BoundaryAction ports into input_ports (U_c) and disturbance_ports (W).
  2. DST-001 verification: checks that disturbance-tagged blocks are not wired to Policy blocks.

DST-001: Disturbance Routing Check

Invariant: No component of W appears in the domain of g.

A disturbance-tagged BoundaryAction must route to Mechanism blocks (the f pathway), never to Policy blocks (the g pathway). Routing a disturbance through Policy would mean the controller can observe and act on it, which contradicts its classification as a disturbance.

Wiring target Allowed? Rationale
Mechanism Yes Disturbance enters f directly
Policy No (DST-001 ERROR) Would place W in domain of g
ControlAction Yes Output map C may depend on disturbances
BoundaryAction N/A BoundaryActions have no forward_in

Modeling Guidelines

When to tag as disturbance

Tag a BoundaryAction as a disturbance when:

  • The input represents noise, perturbation, or environmental forcing
  • No controller in the system observes or reacts to this specific input
  • The input affects state dynamics directly (e.g., wind on a drone, noise on a sensor reading, demand shock on inventory)

When NOT to tag as disturbance

Do not tag as disturbance when:

  • The input is observed by a sensor and fed to a controller
  • The input represents a setpoint, reference signal, or user command
  • A policy block explicitly takes this input as part of its decision

Example: Thermostat with Wind Disturbance

import gds

# Controlled input -- feeds the policy
setpoint = gds.BoundaryAction(
    name="Setpoint",
    interface=gds.interface(forward_out=["Target Temperature"]),
)

# Disturbance -- bypasses policy, enters mechanism directly
wind = gds.BoundaryAction(
    name="Wind",
    interface=gds.interface(forward_out=["Heat Loss"]),
    tags={"role": "disturbance"},
)

controller = gds.Policy(
    name="PID Controller",
    interface=gds.interface(
        forward_in=["Target Temperature"],
        forward_out=["Heater Command"],
    ),
)

heater = gds.Mechanism(
    name="Room Dynamics",
    interface=gds.interface(forward_in=["Heater Command + Heat Loss"]),
    updates=[("Room", "temperature")],
)

The canonical projection will show:

  • input_ports: [("Setpoint", "Target Temperature")] (U_c)
  • disturbance_ports: [("Wind", "Heat Loss")] (W)
  • formula(): h : X -> X (h = f . g); f : X x D x W -> X

Relationship to Existing Theory

The U_c / W partition is a semantic layer extension -- it does not change the underlying composition algebra or compilation pipeline. The partition is derived purely from tags at canonical projection time.

This aligns with control theory's standard plant model:

x_{t+1} = f(x_t, u_t, w_t)

where u_t is the control input and w_t is the disturbance. The GDS framework makes this distinction explicit and verifiable through DST-001.